Custom service
Disulfide Bridges Determination
Assign disulfide connectivity in cysteine-rich peptides
Teams come to this service when they need to assign disulfide connectivity in cysteine-rich peptides. We typically start from partial reduction and labeling, add MS/MS disulfide mapping where the application demands it, and close the loop with NMR cross-check where needed so the final disulfide connectivity assignment report behaves consistently across lots.
Design reviews are part of the schedule, not an extra. Sequence, spacer architecture and analytical strategy are signed off before the first synthesis run, which is why the 3–5 weeks timeline holds in practice.
Confirming folding of disulfide-rich toxins
Batch-to-batch connectivity consistency
Peptides with unresolvable isobaric pairings
Samples requiring containment or licensing we do not hold (BSL-3, radioactive)
Analytical reports follow a fixed template: sample condition on receipt, method description with validation status, raw chromatograms and spectra, results with uncertainty, and an interpretation note. Urgent same-week slots are available for release-critical testing.
Service Highlights
- Partial reduction and labeling as the default route, with MS/MS disulfide mapping held as a proven fallback
- NMR cross-check where needed worked into the design where the application requires it
- Results are reported with detection limits and method validation status, so you know exactly what the number means
- Analytical confirmation of every intermediate before the final release
- Orthogonal methods are used by default — one measurement is an observation, two are data
- Disulfide connectivity assignment report delivered with a complete conjugation or synthesis certificate
How the work runs
Sample intake & plan
Samples are logged with chain of custody and the test matrix for Disulfide Bridges Determination is confirmed.
Method selection
Analytical methods — partial reduction and labeling, MS/MS disulfide mapping — are chosen and their validation status documented.
Measurement
Testing is executed with system-suitability checks and orthogonal confirmation where required.
Data review
Chromatograms and spectra are reviewed by a second analyst before any result is issued.
Reporting
Disulfide connectivity assignment report is issued with detection limits and interpretation notes.
Follow-up support
We discuss anomalies and, where useful, propose the follow-up experiment that resolves them.
Specifications & timeline
- Turnaround
- 3–5 weeks
- Typical scale
- µg – g sample scale
- Chemistry options
- partial reduction and labeling; MS/MS disulfide mapping; NMR cross-check where needed
- Deliverable
- Disulfide connectivity assignment report
- QC package
- Method report, raw data, validated result with detection limits
- Shipping
- Blue ice or ambient by material; chain-of-custody on receipt
Related Products
- Recombinant ProteinsGrowth factors, cytokines and antigens produced across E. coli, yeast, insect and mammalian hosts — over 10,000 items on the shelf and ready to move.
- Native ProteinsIsolated directly from natural sources, preserving native post-translational modifications and conformational epitopes that recombinant systems can miss.
- Monoclonal AntibodiesRecombinant and hybridoma clones characterised for Western blot, IHC, immunofluorescence, ELISA and flow cytometry — application data included.
Next step
Tell us the target, we will tell you what is feasible
Send the sequence, assay format and sensitivity you need. You will get a technical assessment — recommended platform, timeline and the risks worth knowing before you commit budget.