Custom service

High Resolution Conformational Epitope Mapping

Map conformational antibody epitopes at residue resolution

Turnaround: 6–12 weeksTypical scale: µg – g sample scaleChemistry options: HDX-MS epitope mapping; mutagenesis-validated assignment; structural-model integration

Teams come to this service when they need to map conformational antibody epitopes at residue resolution. We typically start from HDX-MS epitope mapping, add mutagenesis-validated assignment where the application demands it, and close the loop with structural-model integration so the final conformational epitope map behaves consistently across lots.

Design reviews are part of the schedule, not an extra. Sequence, spacer architecture and analytical strategy are signed off before the first synthesis run, which is why the 6–12 weeks timeline holds in practice.

Antibody mechanism-of-action studies

IP-strength epitope documentation

Epitopes on denatured-only antigens

Samples requiring containment or licensing we do not hold (BSL-3, radioactive)

Analytical reports follow a fixed template: sample condition on receipt, method description with validation status, raw chromatograms and spectra, results with uncertainty, and an interpretation note. Urgent same-week slots are available for release-critical testing.

Service Highlights

  • HDX-MS epitope mapping as the default route, with mutagenesis-validated assignment held as a proven fallback
  • Structural-model integration worked into the design where the application requires it
  • Results are reported with detection limits and method validation status, so you know exactly what the number means
  • Analytical confirmation of every intermediate before the final release
  • Orthogonal methods are used by default — one measurement is an observation, two are data
  • Conformational epitope map delivered with a complete conjugation or synthesis certificate

How the work runs

  1. Sample intake & plan

    Samples are logged with chain of custody and the test matrix for High Resolution Conformational Epitope Mapping is confirmed.

  2. Method selection

    Analytical methods — HDX-MS epitope mapping, mutagenesis-validated assignment — are chosen and their validation status documented.

  3. Measurement

    Testing is executed with system-suitability checks and orthogonal confirmation where required.

  4. Data review

    Chromatograms and spectra are reviewed by a second analyst before any result is issued.

  5. Reporting

    Conformational epitope map is issued with detection limits and interpretation notes.

  6. Follow-up support

    We discuss anomalies and, where useful, propose the follow-up experiment that resolves them.

Specifications & timeline

Turnaround
6–12 weeks
Typical scale
µg – g sample scale
Chemistry options
HDX-MS epitope mapping; mutagenesis-validated assignment; structural-model integration
Deliverable
Conformational epitope map
QC package
Method report, raw data, validated result with detection limits
Shipping
Blue ice or ambient by material; chain-of-custody on receipt

Related Products

Next step

Tell us the target, we will tell you what is feasible