Custom service

Peptide Stability Optimization

Diagnose peptide instability and engineer stability fixes

Turnaround: 4–8 weeksTypical scale: µg – g sample scaleChemistry options: forced-degradation mapping (oxidation, deamidation, proteolysis); stabilizing-substitution design; formulation screening

Teams come to this service when they need to diagnose peptide instability and engineer stability fixes. We typically start from forced-degradation mapping (oxidation, deamidation, proteolysis), add stabilizing-substitution design where the application demands it, and close the loop with formulation screening so the final stability diagnosis and optimization report behaves consistently across lots.

Design reviews are part of the schedule, not an extra. Sequence, spacer architecture and analytical strategy are signed off before the first synthesis run, which is why the 4–8 weeks timeline holds in practice.

Peptides failing shelf-life targets

Serum-stability improvement programmes

Stability claims without follow-up ICH studies

Samples requiring containment or licensing we do not hold (BSL-3, radioactive)

Analytical reports follow a fixed template: sample condition on receipt, method description with validation status, raw chromatograms and spectra, results with uncertainty, and an interpretation note. Urgent same-week slots are available for release-critical testing.

Service Highlights

  • Forced-degradation mapping (oxidation, deamidation, proteolysis) as the default route, with stabilizing-substitution design held as a proven fallback
  • Formulation screening worked into the design where the application requires it
  • Results are reported with detection limits and method validation status, so you know exactly what the number means
  • Analytical confirmation of every intermediate before the final release
  • Orthogonal methods are used by default — one measurement is an observation, two are data
  • Stability diagnosis and optimization report delivered with a complete conjugation or synthesis certificate

How the work runs

  1. Sample intake & plan

    Samples are logged with chain of custody and the test matrix for Peptide Stability Optimization is confirmed.

  2. Method selection

    Analytical methods — forced-degradation mapping (oxidation, deamidation, proteolysis), stabilizing-substitution design — are chosen and their validation status documented.

  3. Measurement

    Testing is executed with system-suitability checks and orthogonal confirmation where required.

  4. Data review

    Chromatograms and spectra are reviewed by a second analyst before any result is issued.

  5. Reporting

    Stability diagnosis and optimization report is issued with detection limits and interpretation notes.

  6. Follow-up support

    We discuss anomalies and, where useful, propose the follow-up experiment that resolves them.

Specifications & timeline

Turnaround
4–8 weeks
Typical scale
µg – g sample scale
Chemistry options
forced-degradation mapping (oxidation, deamidation, proteolysis); stabilizing-substitution design; formulation screening
Deliverable
Stability diagnosis and optimization report
QC package
Method report, raw data, validated result with detection limits
Shipping
Blue ice or ambient by material; chain-of-custody on receipt

Related Products

Next step

Tell us the target, we will tell you what is feasible

Send the sequence, assay format and sensitivity you need. You will get a technical assessment — recommended platform, timeline and the risks worth knowing before you commit budget.