Custom service

Structure Activity Relationship (SAR) Analysis

Analyze peptide sar data and design the next analog round

Turnaround: 2–5 weeksTypical scale: µg – g sample scaleChemistry options: systematic SAR matrix design; trend extraction across analog panels; next-round candidate design

The service is built around systematic SAR matrix design. Depending on the molecule we may move to trend extraction across analog panels or next-round candidate design to improve stability, loading or yield, and every batch is released with SAR analysis memo with next-round design.

Because Structure Activity Relationship (SAR) Analysis projects usually feed a downstream assay or preclinical study, we lock the release specification early — purity, identity and functional readouts are agreed at quotation, not discovered at delivery.

Interpreting noisy analog data

Prioritizing synthesis budgets

SAR conclusions without reproducible assay data

Samples requiring containment or licensing we do not hold (BSL-3, radioactive)

Analytical reports follow a fixed template: sample condition on receipt, method description with validation status, raw chromatograms and spectra, results with uncertainty, and an interpretation note. Urgent same-week slots are available for release-critical testing.

Service Highlights

  • Systematic SAR matrix design as the default route, with trend extraction across analog panels held as a proven fallback
  • Next-round candidate design worked into the design where the application requires it
  • Results are reported with detection limits and method validation status, so you know exactly what the number means
  • Analytical confirmation of every intermediate before the final release
  • Orthogonal methods are used by default — one measurement is an observation, two are data
  • SAR analysis memo with next-round design delivered with a complete conjugation or synthesis certificate

How the work runs

  1. Sample intake & plan

    Samples are logged with chain of custody and the test matrix for Structure Activity Relationship (SAR) Analysis is confirmed.

  2. Method selection

    Analytical methods — systematic SAR matrix design, trend extraction across analog panels — are chosen and their validation status documented.

  3. Measurement

    Testing is executed with system-suitability checks and orthogonal confirmation where required.

  4. Data review

    Chromatograms and spectra are reviewed by a second analyst before any result is issued.

  5. Reporting

    SAR analysis memo with next-round design is issued with detection limits and interpretation notes.

  6. Follow-up support

    We discuss anomalies and, where useful, propose the follow-up experiment that resolves them.

Specifications & timeline

Turnaround
2–5 weeks
Typical scale
µg – g sample scale
Chemistry options
systematic SAR matrix design; trend extraction across analog panels; next-round candidate design
Deliverable
SAR analysis memo with next-round design
QC package
Method report, raw data, validated result with detection limits
Shipping
Blue ice or ambient by material; chain-of-custody on receipt

Related Products

Next step

Tell us the target, we will tell you what is feasible

Send the sequence, assay format and sensitivity you need. You will get a technical assessment — recommended platform, timeline and the risks worth knowing before you commit budget.