Custom service
Tetramer-Positive T Cell Sorting
Sort tetramer-positive t cells for cloning, expansion or sequencing
Tetramer-Positive T Cell Sorting supports programmes that sort tetramer-positive T cells for cloning, expansion or sequencing. In a typical engagement we plan the FACS sorting with tetramer panels route first, confirm compatibility with post-sort viability and recovery QC, and release sorted cell fraction with purity certificate on a 2–4 weeks schedule.
Chemistry is chosen for the molecule, not from a menu. Where the payload tolerates it we keep FACS sorting with tetramer panels as the primary option and hold post-sort viability and recovery QC in reserve, so that scale-up never depends on an unproven step.
TCR sequencing and clone derivation
Antigen-specific line establishment
Sorting requiring clinical-grade (GMP) release
Alleles or peptides with no published refolding precedent and no feasibility budget
Each tetramer lot is tested functionally, not just biochemically: a known antigen-specific T cell line or clone is stained, and the lot is released only if the staining profile meets the agreed specification. Allele and peptide identity are confirmed by MS.
Service Highlights
- FACS sorting with tetramer panels as the default route, with post-sort viability and recovery QC held as a proven fallback
- Single-cell compatibility worked into the design where the application requires it
- Refolding yield and monomer integrity confirmed by SEC before tetramerization
- Analytical confirmation of every intermediate before the final release
- Fluorescent labels chosen and titrated so staining signal stays in the linear range
- Sorted cell fraction with purity certificate delivered with a complete conjugation or synthesis certificate
How the work runs
Construct design
Allele, peptide and biotinylation acceptor peptide are confirmed, and the expression construct strategy is agreed.
Inclusion body preparation
Heavy chain and β2-microglobulin are expressed and purified as inclusion bodies.
Refolding
Chain, β2M and peptide are folded together under redox-buffered conditions optimized for the allele.
Biotinylation & purification
Monomer is BirA-biotinylated and polished by SEC-HPLC to remove aggregates.
Tetramerization
Fluorescent streptavidin is titrated in to form stable tetramers with controlled label ratio.
Functional release
Sorted cell fraction with purity certificate is released after flow-cytometry binding confirmation against the specification.
Specifications & timeline
- Turnaround
- 2–4 weeks
- Typical scale
- 50 µg – 1 mg tetramer per construct
- Chemistry options
- FACS sorting with tetramer panels; post-sort viability and recovery QC; single-cell compatibility
- Deliverable
- Sorted cell fraction with purity certificate
- QC package
- SEC-HPLC monomer integrity, biotinylation ratio, flow-cytometry binding test
- Shipping
- Dry ice, aliquoted to avoid freeze-thaw
Related Products
- Recombinant ProteinsGrowth factors, cytokines and antigens produced across E. coli, yeast, insect and mammalian hosts — over 10,000 items on the shelf and ready to move.
- Native ProteinsIsolated directly from natural sources, preserving native post-translational modifications and conformational epitopes that recombinant systems can miss.
- Monoclonal AntibodiesRecombinant and hybridoma clones characterised for Western blot, IHC, immunofluorescence, ELISA and flow cytometry — application data included.
Next step
Tell us the target, we will tell you what is feasible
Send the sequence, assay format and sensitivity you need. You will get a technical assessment — recommended platform, timeline and the risks worth knowing before you commit budget.