Custom service

Endotoxin Removal Service

Below the LAL threshold, without destroying the protein.

Target levels: Below 1 EU/mg standard; below 0.1 EU/mg for sensitive applicationsMethods: Triton X-114 phase separation, polymyxin B resin, histamine resin, ion exchange, TFFScale: 1 mg to 10 g per batch

Endotoxin is invisible to protein QC and decisive for the experiment. A preparation at 50 EU/mg will activate TLR4 in any cell assay, confound an immunisation study and fail an in vivo review. Removal is therefore a standard requirement, and the difficulty is that the standard methods trade one problem for another: detergent phase separation can strip membrane-associated proteins of their activity, and affinity resins can bind the protein itself.

The method is matched to the protein. Triton X-114 phase separation removes endotoxin efficiently for robust proteins that tolerate detergent exposure. Affinity-based removal — polymyxin B or histamine-coupled resins — works for proteins that do not bind the resin. Ion exchange and size exclusion remove endotoxin incidentally where the charge or size difference allows. For high-purity requirements, two methods are combined, and the sequence is chosen from a small-scale trial rather than from habit.

Verification is by LAL assay, reported per lot with the removal method stated. Where the protein will be used in sensitive systems, the LAL result is supported by a functional check — a TLR4-responsive cell assay — because LAL can be interfered with by some buffers and proteins, and an interfered assay reports a false pass.

Endotoxin removal is required for every batch destined for cell-based assays, immunisation, in vivo work or any TLR-sensitive system — which in practice is most biologics work.

It cannot rescue a protein that the removal method destroys; the small-scale stability trial exists to catch that, and when no method preserves activity, the honest outcome is a buffer or formulation change upstream.

Each batch ships with LAL endotoxin value, the removal sequence with per-step contributions, activity retention against the pre-removal aliquot, and where relevant, a TLR4 functional check. Consumable lot numbers are recorded for endotoxin traceability.

Service Highlights

  • Method matched to protein. Detergent, affinity, ion exchange and membrane methods compared on a small aliquot before the batch is processed.
  • Activity verified after removal. Binding or enzymatic activity measured before and after, since the removal method can cost more activity than the endotoxin cost the experiment.
  • LAL plus functional check. TLR4-responsive cell assay used where LAL interference is suspected, so a false pass is caught.
  • Endotoxin-free consumables. Low-endotoxin buffers, columns and vessels throughout, since re-introduction during processing is the common failure.
  • Documented sequence. The removal steps recorded with their individual contributions, so the process can be repeated.
  • Tight targets. Below 0.1 EU/mg achievable for in vivo and cell-based work.

How the work runs

  1. Starting assessment

    Current endotoxin level measured; protein stability to detergent and resin contact tested on a small aliquot.

  2. Method selection

    Removal sequence chosen from the stability data and the target specification.

  3. Removal run

    Methods executed under endotoxin-controlled conditions, with buffers and consumables verified low-endotoxin.

  4. LAL testing

    Endotoxin measured by LAL at each step, with the final lot against the specification.

  5. Functional check

    TLR4-responsive assay where the application is cell-based or in vivo, to exclude LAL interference.

  6. Release

    Certificate with endotoxin value, removal method, activity retention and mass balance.

Specifications & timeline

Target levels
Below 1 EU/mg standard; below 0.1 EU/mg for sensitive applications
Methods
Triton X-114 phase separation, polymyxin B resin, histamine resin, ion exchange, TFF
Scale
1 mg to 10 g per batch
Verification
LAL assay, optional TLR4 cell-based functional check
Timeline
1–2 weeks per batch

Related Products

Next step

Tell us the target, we will tell you what is feasible

Send the sequence, assay format and sensitivity you need. You will get a technical assessment — recommended platform, timeline and the risks worth knowing before you commit budget.