Custom service

Enzyme Immobilization

An enzyme on a solid support, still active after its fiftieth cycle.

Supports: Agarose, magnetic beads, silica, polymer resins, membranesChemistry: NHS, epoxy, aldehyde, maleimide, Ni-NTA, Strep, streptavidin, site-directedLoading: 1–20 mg protein per gram support, verified by protein and activity assay

Immobilised enzymes earn their keep through reuse and easy separation — but only if the immobilisation chemistry preserves activity. Random covalent coupling through surface lysines is fast and cheap, and it routinely costs 30–70% of activity by modifying residues near the active site or fixing the enzyme in an unfavourable orientation. The design question is where the enzyme is attached, not merely whether it is attached.

Three strategies cover the practical cases. Random covalent coupling for enzymes with robust, tolerant surfaces. Oriented coupling through an affinity tag — His-tag on Ni-NTA resin, Strep-tag, biotin-streptavidin — placing the active face away from the support. Site-directed covalent attachment through an engineered cysteine or enzymatic handle for production-grade immobilisation where the support will see repeated industrial cycles. Leaching, activity retention and reuse cycles are measured for each.

The characterisation reflects what the user will actually do with it: activity per gram of support, reuse performance over the intended number of cycles, storage stability of the wet and dry preparation, and protein loading measured rather than assumed. A support that looks fully loaded but carries inactive protein is the most common failure, and loading is verified by both protein assay and activity assay.

Immobilisation fits enzymes used repeatedly — biocatalysis, diagnostic reagent strips, affinity purification supports — and processes where enzyme removal from the product stream is the point.

It is not worthwhile for single-use applications, and it cannot rescue an enzyme that is intrinsically unstable on surfaces; some proteins denature on any support, and the coupling screen identifies those before scale-up.

Each preparation is delivered with protein loading, activity per gram of support, reuse performance over the agreed cycle count, leaching per cycle, and storage stability for the wet and dry formats. The unbound fraction after coupling is quantified so mass balance is visible.

Service Highlights

  • Oriented strategies. Affinity tags and site-directed chemistry place the active face away from the support, protecting activity.
  • Reuse performance measured. Activity tracked over the intended number of cycles — the number that matters, not a generic stability claim.
  • Loading verified two ways. Protein assay and activity assay both reported, so inactive bound protein is visible.
  • Leaching quantified. Protein released into the reaction stream measured per cycle, critical for processes with product purity requirements.
  • Support matched to process. Magnetic beads for easy recovery, agarose for column work, silica or polymer resins for flow formats.
  • Storage formats. Wet slurry and dry preparations both validated for storage stability.

How the work runs

  1. Enzyme and support assessment

    Enzyme surface, stability and intended cycle count reviewed; support and chemistry selected.

  2. Coupling optimisation

    Chemistry conditions titrated at small scale, with activity retention as the selection criterion.

  3. Preparative immobilisation

    Coupling run at the required scale under the selected condition.

  4. Loading verification

    Protein loading by assay and activity per gram of support measured; unbound protein quantified.

  5. Reuse testing

    Activity tracked over repeated reaction cycles, with leaching measured per cycle.

  6. Storage validation

    Wet and dry preparations stored under defined conditions and retested.

Specifications & timeline

Supports
Agarose, magnetic beads, silica, polymer resins, membranes
Chemistry
NHS, epoxy, aldehyde, maleimide, Ni-NTA, Strep, streptavidin, site-directed
Loading
1–20 mg protein per gram support, verified by protein and activity assay
Reuse
Validated to the intended cycle count with leaching data
Timeline
2–3 weeks per immobilisation

Related Products

Next step

Tell us the target, we will tell you what is feasible

Send the sequence, assay format and sensitivity you need. You will get a technical assessment — recommended platform, timeline and the risks worth knowing before you commit budget.